Command Data Group
The IoT EIE allows a user to write a payload using a command manually through the "Command" (Command) data group using the data group editor or via a UIS command. Sample commands (NPublish and DPublish) are defined in the device template file.
See UIS Command Component Parameters for more information.
DPublish
This command sends a device command. Commands are defined in the device template file in the "commands" section for a data group.
NPublish
This command sends an edge-node command. Commands are defined in the device template file in the "commands" section for a data group.
Configuring the Command Data Group
The Command data group is configured within the View Data dialog box of the data group. To configure the Topic section, see the IoT EIE Data Group Properties table. The following is an example of a View Data dialog box for a Command data group.
|
Command Data Group |
To configure the command for a Command data group, make selections from the fields below the Topic section.
| Property | Description |
|---|---|
|
Command |
The type of command. Select an option from the drop-down menu. Commands are defined in the device template file. |
|
Description |
Displays the description of the command from the device template file, e.g., DPublish, NPublish, etc. |
|
Value |
Displays the value of the command from the device template file (if indicated) or allows an entry in the field when not set in the device template file. |
|
Facility ID.UDC |